Search
Split DC Inverter Heat Pump
Split DC Inverter Air To Water Heat Pump
Model DHP-09 DHP-12 DHP-15 DHP-15S DHP-18S DHP-24S EHP-30S
HP 3 4 5 5 6 8 10
Power supply V/Ph/Hz 200-240V/1Ph/50Hz 380-415V/3Ph/50Hz
+7 / 35 floor heating Heating capacity kW 9 12.0 15.0 15.0 18.0 24.0 30.0
Power input kW 2.1 2.70 3.50 3.40 4.30 5.60 7.30
COP   - 4.2 4.4 4.3 4.4 4.2 4.3 4.1
+2 / 35 floor heating Heating capacity kW 6.8 11.3 12.7 12.7 15.3 21.7 25.6
Power input kW 2.1 3.40 3.85 3.80 4.60 6.60 8.20
COP   - 3.2 3.30 3.30 3.30 3.30 3.30 3.10
-7 / 35 floor heating Cooling capacity kW 6 10.0 11.0 11.0 13.3 18.9 22.3
Power input kW 2.4 3.85 4.40 4.40 5.40 7.60 9.20
EER - 2.5 2.60 2.50 2.50 2.45 2.50 2.40
+7 / 45 radiators Heating capacity kW 7.8 10.3 13.0 13.0 15.3 20.6 25.5
Power input kW 2.4 3.30 4.00 4.00 4.80 6.30 8.20
COP   - 3.2 3.10 3.30 3.30 3.20 3.30 3.10
-7 / 45 radiators Heating capacity kW 7.6 10.1 13.0 13.0 15.2 20.6 25.3
Power input kW 3.4 5.00 6.20 6.20 7.20 9.80 12.60
COP   - 2.2 2.00 2.10 2.10 2.10 2.10 2.00
+35 / 7 fan coil Cooling capacity kW 7 10.0 11.8 11.8 14.5 20.0 25.0
Power input kW 2.6 3.60 4.50 4.50 5.80 7.10 10.00
EER  - 2.7 2.80 2.60 2.60 2.50 2.80 2.50
Noise level DB(A) 52 53 55 55 55 56 56
Rated outlet water temp. °C   7~55
Max outlet water temp. °C   60
Ambient temperature range °C   -20~43
Rated water flow rate L/S 0.43 0.57 0.72 0.72 0.86 1.15 1.43
Rated pressure drop kPa 30 40 45 45 45 40 47
Max. Working Pressure Refrigerant Bar 44 44 44 44 44 44 44
Water Bar 7 7 7 7 7 7 7
Water connection  inch 1" 1" 1" 1" 1" 1-1/4" 1-1/4"
Controller -    Micro processor based digital wire controller with LCD display
External cabinet -   Galvanized steel with powder coating
Compressor  Make - Panasonic Hitachi
Type - Rotary Scroll
Nos. - 1 1 1 1 1 1 1
Refrigerant   R410A
Refrigerant amount Kg 1.45 1.9 2.5 2.5 2.6 4.2 4.5
Water heat exchanger Type -   Brazed plate heat exchanger
Materials - SUS 316
Copper pipe Diameter Gas/Liquid inch 5/8"/1/4" 5/8"/3/8" 3/4"/3/8" 7/8"/1/2"
Built in electric heater KW 3 3 3 3 3 3 3
Built in 3-way valve - yes yes yes yes yes yes yes
Built in pump - Wilo/Xinhu
Dimension
(W*D*H)
Indoor Unit
(Free Standing Type)
mm 660*650*1150 660*650*1150 660*650*1150 660*650*1150 660*650*1150 660*650*1250 660x650x1250
Indoor Unit
(Wall Mounted Type)
mm 508*406*947 508*406*947 508*406*947 508*406*947 508*406*947 508*406*1000 508*406*1000
Outdoor Unit mm 880*360*780 830*310*1230 830*310*1260 930*390*1270 930*390*1270 1105x515x1500 1105x515x1500
Note:                  
1.The values of heating(cooling) capacity/power input/COP(EER) are based on measurement of EN14511 standard.Usage environment,such as operation of the heating equipment,room temperature,and controller adjustments, may cause disparities between practically determined and these values.                                                            
2.Sound pressure level measured at distance of 1m from the device.                                                                                                                                                                                         
3.For Free standing type, the compressor is located in the indoor unit; While for Wall Mounted Type, the compressor is located in the outdoor unit.
Products Search
脚注信息
Copyright(C)since2017   DONGGUAN KEYANG ENERGY-SAVING EQUIPMENT TECHNOLOGY CO.LTD